4000-520-616
欢迎来到免疫在线!(蚂蚁淘生物旗下平台)  请登录 |  免费注册 |  询价篮
主营:常规产品包括:丝氨酸蛋白酶、蛋白酶抑制剂、中性粒细胞酶、载脂蛋白、脂蛋白,血小板蛋白、转铁蛋白、免疫球蛋白
咨询热线电话
4000-520-616
当前位置: 首页 > 产品中心 > peptide > Athens Research/Cambio - Excellence in Molecular Biology/25 rxns/34-7025
商品详细Athens Research/Cambio - Excellence in Molecular Biology/25 rxns/34-7025
Athens Research/Cambio - Excellence in Molecular Biology/25 rxns/34-7025
Athens Research/Cambio - Excellence in Molecular Biology/25 rxns/34-7025
商品编号: 34-7025
市场价: ¥0.00
美元价: 0.00
产地: 美国(厂家直采)
公司:
产品分类: 多肽合成
公司分类: peptide
联系Q Q: 3392242852
电话号码: 4000-520-616
电子邮箱: info@ebiomall.com
商品介绍
Cell culture contamination control

Cell culture contamination control: Detection

Detection and identification of Mycoplasma

  • Catalogue
  • Description
  • Protocols
  • References
  • Notes
  • Applications & Benefits

AquaScreen® PCR Detection kits - detection of Escherichia coli

The AquaScreen® Escherichia coli qPCR Detection Kit is used for DNA samples prepared with the AquaScreen® FastExtract procedure for quantification of Escherichia coli in water samples.

Minerva Biolabs

Catalogue No.DescriptionPack SizePriceQty
  • Change to:
  • €
34-7025AquaScreen® Escherichia coli25 rxns£240.00QuantityAdd to Order
34-7100AquaScreen® Escherichia coli100 rxns£868.00QuantityAdd to Order
34-7250AquaScreen® Escherichia coli250 rxns£1,929.00QuantityAdd to Order

AquaScreen® PCR Detection kits - detection of Escherichia coli

The AquaScreen® Escherichia coli qPCR Detection Kit is used for DNA samples prepared with the AquaScreen® FastExtract procedure for quantification of Escherichia coli in water samples.

Minerva Biolabs

AquaScreen® Escherichia coli

Type of PCR

Quantitative real-time PCR (qPCR)

The AquaScreen® Escherichia coli qPCR Detection Kit is used for DNA samples prepared with the AquaScreen® FastExtract procedure for quantification of Escherichia coli in water samples.

Recommended Use / Scope

Applicable in research and industry for QA testing of household and process water. Not recommended for clinical diagnostics, testing of human samples or pharmaceutical products.

Kit Components

Freeze-dried primer, probes, nucleotides and polymeraseRehydration BufferFreeze-dried Positive Control DNAFreeze-dried Internal Amplification Control

AquaScreen flyer

If you cannot find the answer to your problem below then please contact us or telephone 01954 210 200

AquaScreen® PCR Detection kits - detection of Escherichia coli

The AquaScreen® Escherichia coli qPCR Detection Kit is used for DNA samples prepared with the AquaScreen® FastExtract procedure for quantification of Escherichia coli in water samples.

Minerva Biolabs

Instructions for use

MSDS

If you cannot find the answer to your problem below then please contact us or telephone 01954 210 200

AquaScreen® PCR Detection kits - detection of Escherichia coli

The AquaScreen® Escherichia coli qPCR Detection Kit is used for DNA samples prepared with the AquaScreen® FastExtract procedure for quantification of Escherichia coli in water samples.

Minerva Biolabs

Felföldi T. et al., (2010). Detection of potentially pathogenic bacteria in the drinking water distribution system of a hospital in Hungary. Clinical Microbiology and Infection, 16: 89–92 10.1111/j.1469-0691.2009.02795.x.

Kirschner A.K. (2016). Determination of viable legionellae in engineered water systems: Do we find what we are looking for?

Water Research, 93:276-88. doi: 10.1016/j.watres.2016.02.016.

Rozwadowska B. et al., (2013). Application of a real-time PCR method for Salmonella spp., Escherichia coli, Staphylococcus aureus and Clostridium perfringens detection in water samples. Polish Journal of Microbiology, 62(4):439-43.

Vogel J. et al., (2013). Impacts of Migratory Sandhill Cranes (Grus canadensis) on Microbial Water Quality in the Central Platte River, Nebraska, USA. Water, Air and Soil Pollution, 224:1576. doi: 10.1007/s11270-013-1576-3.

Yaradou D.F. et al., (2007). Integrated real-time PCR for detection and monitoring of Legionella pneumophila in water systems. Applied and Environmental Microbiology, 73(5):1452-6. doi: 10.1128/AEM.02399-06.

If you cannot find the answer to your problem below then please contact us or telephone 01954 210 200

AquaScreen® PCR Detection kits - detection of Escherichia coli

The AquaScreen® Escherichia coli qPCR Detection Kit is used for DNA samples prepared with the AquaScreen® FastExtract procedure for quantification of Escherichia coli in water samples.

Minerva Biolabs

Required Consumables

PCR reaction tubes

Optional: For calibration we recommend our Escherichia coli DNA CalibrationReagent (Cat.-No. 52-0083).

Required lab devices

Pipetting equipment

qPCR cycler with filter sets for FAM™ and ROX™

Shelf Life and Storage

Components are maintainable at2 to8 °C for at least 6 months. After rehydratisation the reagents must be stored at -18 °C.

If you cannot find the answer to your problem below then please contact us or telephone 01954 210 200

AquaScreen® PCR Detection kits - detection of Escherichia coli

The AquaScreen® Escherichia coli qPCR Detection Kit is used for DNA samples prepared with the AquaScreen® FastExtract procedure for quantification of Escherichia coli in water samples.

Minerva Biolabs

Recommended Use / Scope

Applicable in research and industry for QA testing of household and process water. Not recommended for clinical diagnostics, testing of human samples or pharmaceutical products.

If you cannot find the answer to your problem below then please contact us or telephone 01954 210 200

品牌介绍
Athens Research & Technology—供应多款蛋白、酶制品 Athens Research & Technology是成立于2010年的新兴生物高科技制品公司,该公司拥有BSL-2实验室及超过11000平方英尺的cGMP生产厂房,并且通过ISO 9001:2008认证。Athens公司致力于纯化分离高纯度,高活性的人类蛋白质及研发多克隆抗血清产品。提供包括高纯度及活性的丝氨酸蛋白酶,蛋白酶抑制剂,中性粒细胞酶,载脂蛋白,脂蛋白,血小板蛋白,转铁蛋白,免疫球蛋白等等。公司产品适用于炎症,冠状动脉疾病,自身免疫性疾病,癌症,阿尔茨海默氏病等众多研究领域,已被世界*制药公司及诊断试剂公司用于体外诊断试剂盒/免疫检测试剂盒、药物筛选、细胞培养液(包括干细胞)等产品研发。除了人类蛋白质,我们还从动物血清和组织中分离多种蛋白质及酶类。此外,Athens Research and Technology还提供特殊试剂/蛋白定制服务,以满足研究人员的不同需求。